Product description
VenoSeal™ is an individually adjustable penile constriction loop for men who can achieve a natural erection but have difficulty maintaining it for a sufficient period of time. One possible cause is a condition known as venous leak, in which blood cannot be adequately retained in the penis during an erection.
The constriction loop is placed around the base of the penis and adjusted individually. The applied pressure reduces venous blood outflow, helping to maintain the erection for longer. The soft, flexible material ensures comfortable use. VenoSeal™ is reusable and can be easily cleaned after use.
Application and Handling
VenoSeal™ should ideally be applied before a full erection is achieved.
- Apply the loop: Stretch the loop, slide it over the penis and position it at the base of the penis.
- Position the loop: The end with the ball should face upwards.
- Adjust the tension: Pull the end with the grip tab without the ball until the loop fits gently around the base of the penis. Apply only as much tension as necessary to maintain the erection.
- Release the loop: Pull the end with the ball upwards to release the tension. Then remove the loop completely.
Important information:
- Maximum wearing time: 30 minutes. The loop must not be worn for longer than 30 minutes. Never fall asleep while wearing the loop. Prolonged use may cause permanent injury or damage to the penis.
- Allow at least 60 minutes between applications.
- Use the minimum tension necessary to maintain the erection. Excessive pressure may cause pain, bruising or injury.
- If pain or other discomfort occurs, release the loop. Seek medical advice if symptoms persist.
- In the presence of certain medical conditions, particularly blood clotting disorders, or when taking blood-thinning medication, having a penile implant or having Peyronie’s disease, the contraindications and precautions in the Instructions for Use must be observed.
- Erectile dysfunction should be medically evaluated, as it may indicate underlying medical conditions.
Please read the Instructions for Use supplied with the product before use.
Cleaning and Care
VenoSeal™ can be cleaned after use with warm water and ordinary hand soap. Allow it to dry and store it at room temperature.
Only water-based lubricants should be used. The loop should be replaced after six months of use or if visible signs of wear appear.
| Article number | Availability* |
|---|---|
| TM-16-07 | ✅ In stock in Zuchwil |
| Included in delivery per package: 1 piece |
*Orders received by 4:00 p.m. on business days are dispatched the same day via A-Post.
Please note: on the day before a public holiday, we can accept orders until 2:00 p.m.
If you have any questions about our products, Stephan Clément will be happy to assist you as your contact person.
Certificates and memberships